ANSI/ASHRAE 62.2-2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Bldgs (PDF Download)
The PDF/Redline Download option contains PDF files of both the I-Code and a Redline version of the I-Code which shows changes from the previous edition marked in the color red. With the Redline you can see what has been changed from the previous edition. This option is a searchable PDF download that requires a PDF Reader. It is mobile compatible with mobile tablets and smart phones that support the PDF format. The PDF Download is licensed per individual, who may place the file on up to four electronic devices for their personal use. Distribution of the PDF is not permitted. For a volume license the PDF is licensed to the person to which it is assigned. Use on a local area network or other network is not permitted.
This standard defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality in low-rise residential buildings. It is ASHRAE's IAQ standard for residential buildings.
It applies to spaces intended for human occupancy within single-family houses and multi-family structures of three stories or fewer above grade, including manufactured and modular houses. This standard does not apply to transient housing such as hotels, motels, nursing homes, dormitories, or jails.
Since 2003, extensive experience has been gained in the application of this standard, due to its adoption by various building codes and use in numerous building programs. As such, many clarifications and improvements have been identified and incorporated through the approved addenda. One significant addition is the new normative appendix addressing the application of the standard to existing buildings.
| Description: Links | |
|---|---|
| Description: | This standard defines the roles of and minimum requirements for mechanical and natural ventilation systems and the building envelope intended to provide acceptable indoor air quality in low-rise residential buildings. It is ASHRAE's IAQ standard for residential buildings. It applies to spaces intended for human occupancy within single-family houses and multi-family structures of three stories or fewer above grade, including manufactured and modular houses. This standard does not apply to transient housing such as hotels, motels, nursing homes, dormitories, or jails. Since 2003, extensive experience has been gained in the application of this standard, due to its adoption by various building codes and use in numerous building programs. As such, many clarifications and improvements have been identified and incorporated through the approved addenda. One significant addition is the new normative appendix addressing the application of the standard to existing buildings. |
| Pages | 38 |
| Code Year | - Other - |
| Publisher | ASHRAE |
| Language | English |