ANSI/ASHRAE/ACCA 180-2008 Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems (PDF Download)
The PDF/Redline Download option contains PDF files of both the I-Code and a Redline version of the I-Code which shows changes from the previous edition marked in the color red. With the Redline you can see what has been changed from the previous edition. This option is a searchable PDF download that requires a PDF Reader. It is mobile compatible with mobile tablets and smart phones that support the PDF format. The PDF Download is licensed per individual, who may place the file on up to four electronic devices for their personal use. Distribution of the PDF is not permitted. For a volume license the PDF is licensed to the person to which it is assigned. Use on a local area network or other network is not permitted.
Referenced in the 2012 IMC, IRC. Standard 180 was created in a collaborative effort between ASHRAE and ACCA, the Air Conditioning Contractors of America. Its intent is to address the often inconsistent practices for inspecting and maintaining HVAC systems in commercial, institutional and other buildings where the public may be exposed to the indoor environment. Current practices in such buildings vary widely today. Many facilities choose to follow rigorous policies that maintain the system in new or nearly new condition. Others either lack policy in this area or have adopted a run-to-failure approach where the system or components of the system are attended to only when there is a failure.
NOTE: This standard is specifically focused on the impacts of maintenance on occupant thermal comfort, indoor air quality and energy efficiency. Ancillary maintenance issues related to equipment reliability, equipment robustness and minimizing overall maintenance costs are also appropriate in order to protect the HVAC capital investment and/or minimize system downtime. These issues, however, are outside of the scope of this standard.
| Description: Links | |
|---|---|
| Description: | Referenced in the 2012 IMC, IRC. Standard 180 was created in a collaborative effort between ASHRAE and ACCA, the Air Conditioning Contractors of America. Its intent is to address the often inconsistent practices for inspecting and maintaining HVAC systems in commercial, institutional and other buildings where the public may be exposed to the indoor environment. Current practices in such buildings vary widely today. Many facilities choose to follow rigorous policies that maintain the system in new or nearly new condition. Others either lack policy in this area or have adopted a run-to-failure approach where the system or components of the system are attended to only when there is a failure. |
| Pages | 26 |
| Code Year | 2012 |
| Publisher | ASHRAE |
| Language | English |